3
GB – Instructions for Series 9000 Masks
Important Information for Users
This manual is only valid in conjunction with the instruction manual for Moldex Series
7000/9000 gas and particulate filters. Failure to comply with these instructions on
how to use the product and failure to wear the respiratory protection in the polluted
area may negatively impact on the health of the user and lead to permanent damage
and life-threatening injuries.
• This breathing apparatus does not supply oxygen (02) • Only use the product in ad
-
equately ventilated areas,(19.5 Vol.-% oxygen) • The mask and filters must be selected
in accordance with the pollutant type and concentration (see Table 2). • In the case
of gases with insufficient warning properties, filters may only be used if special usage
policies are specified for this purpose. • If the conditions are uncertain or changeable,
self-contained breathing apparatus must be worn. • You must exit the working area
and replace the respirator mask immediately if: – the mask is damaged, – you expe
-
rience difficulty in breathing, – you experience dizziness or fatigue. – you can taste
or smell hazardous substances or if you experience irritation • Read the instruction
manual before using the mask. • The product does not contain any metallic parts that
could cause ignition in potentially explosive atmospheres. • If you have any questions
about how to use the product, please contact Moldex-Metric. • You must also observe
the relevant rules and regulations when using respiratory equipment. • Under certain
circumstances, persons with beards, long sideburns or other anomalies in the area
around the sealing lines may be unable to achieve a proper sealing fit. Spectacle
frames that extend under the sealing line will impede a proper sealing fit. • The masks
must not be modified in any way. • Users of the masks and filters must be familiar with
how to handle them correctly. • When not in use, the mask and filter must be stored in
an uncontaminated environment.
Caution: Do not use filter equipment in unventilated containers and confined spaces.
Preparations Before Using the Full-mask
The full-mask must always be checked before use. Do not use a damaged or defective
mask. Seek the immediate assistance of a supervisor.
You must check • The mask and the filters for fractures, deformations, cracks and
contamination. • Whether the head strap is torn, nicked or damaged in any other way
and whether it provides sufficient elasticity. • The inhalation and exhalation valves
as well as the sealing rings on the filter connections for contamination, deformation,
fractures and cracks. Make sure that the valves and sealing rings are fitted correctly. •
The use-by-date of the filter and their correct fitting in accordance with the instruction
manual for gas and particulate filters. Fitting/removing the full-mask (Figures 1, 2, 3
and 4) Open the straps fully at the 4 adjustment points and hold the head strap with
one hand at the bracing with the Moldex lettering. Place the opening of the head strap
at the back of the neck and pull the mask down over your face from above. At this point,
make sure that no hairs are trapped between the sealing lip and your face. Position
the mask on your face and use one hand to press the mask firmly against your mouth
and chin. Now use your other hand to pull the neck strap tight on one side and then
repeat the procedure on the other side. To ensure the best possible seal between mask
and face, you should always tighten the neck straps first. The head strap must lie flat
on your head. To ensure that the mask fits comfortably, adjust the head and neck strap
equally. Before entering your working area, check that the mask creates a seal around
the face. To remove the mask, first loosen the clips on the neck strap by pulling the mask
away from your face. Using suction to check the face seal (Figure 5) Place the palm
of your hand over the opening on the filter cover to seal it and breathe in slowly. If the
facepiece contracts slightly, the mask is correctly seated. If you notice an inflow of air,
adjust the position of the mask on your face or adjust the tension of the straps. Repeat
this check until a seal is achieved. Using excess pressure to check the face seal (Figure
6) For full-masks equipped with an EN 148-1 connection, check the face seal before
fitting the filter to the facepiece. Place the palm of your hand over the exhalation valve
and breathe out slowly. If no air escapes between the facepiece and your face, a prop
-
er sealing fit is achieved. If you notice air escaping, adjust the position of the mask on
your face or adjust the tension of the straps. Repeat this check until a seal is achieved.
Under no circumstances should you enter a hazardous area if you are unable to
achieve a proper sealing fit. Seek the assistance of a supervisor.
Maintaining the Full-mask
The maintenance intervals as set out in the national regulations must be adhered to.
The date of manufacture is shown on the inside of the face seal in the chin area.
Cleaning/Disinfection We recommend cleaning the mask after each use. If not in use,
clean the mask after 6 months at the latest. Remove the filter; clean the facepiece
with warm water (max. 50°C). If necessary, use a neutral cleaning agent and an
alcohol-based disinfectant. To clean the valve membrane, remove it from the holder.
To clean the inner mask, unfasten it from the two stop points. To refit it, use the guide
rails on the lower part of the lens and the two stop points. To dismantle the filter, refer
to the instruction manual for gas and particulate filters. After having cleaned or disin
-
fected the mask, the face seal needs to be checked by means of suitable leak testing
equipment. Before cleaning pull the protective film away from the lens Dry the mask
thoroughly before putting on a new protective film and before storing it. Storage Keep
the 9000 mask sealed in a dry, uncontaminated environment. Protect against sunlight
and sources of heat (see the "Storage" icons). The name of the wearer and a record
of the filter changes can be noted on the packaging. Caution: At low temperatures,
moisture can cause the valves to freeze up. The date of manufacture is engraved on
the inside of the mask. Calendar clocks see page 39. Exhalation Valve (Spare Part
No. 9974 [b]) Fold down the cover of the exhalation valve and check the exhalation
valve and valve seat for contamination, deformation, fractures or cracks. Replace the
valve membrane when necessary, or every 4 years at the latest. Please note date of
replacement. Inhalation Valve (Spare Part No. 9974 [a]) Check the inhalation valve
on the inner mask and on the inside of the filter connection for contamination, defor
-

Klepetajte s priročnikom za izdelek Moldex Series 9000 EasyLock z uporabo AI

Pridobite takojšnje odgovore AI iz priročnika za izdelek Moldex Series 9000 EasyLock

Vprašajte karkoli o izdelku Moldex Series 9000 EasyLock. Odgovori prihajajo iz tega priročnika, s strani, na katerih temeljijo.

Series 9000 EasyLock Urnik vzdrzevanja

Opomni me, ko je potrebno vzdrzevanje
Vsakih 6 mesecev
Čiščenje neuporabljene maske

Če maska ni v uporabi, jo očistite vsaj vsakih 6 mesecev za zagotavljanje higiene in delovanja.

Vsaka 4 leta
Zamenjava membrane izdihavnega ventila

Po potrebi zamenjajte membrano izdihavnega ventila ali najpozneje vsaka 4 leta. Zabeležite datum zamenjave.

Po vsaki uporabi
Čiščenje in razkuževanje maske

Odstranite filtre in obrazni del očistite s toplo vodo (max 50°C). Po potrebi uporabite nevtralno čistilo/alkoholno razkužilo. Po čiščenju preverite tesnjenje.

Pred vsako uporabo
Pregled maske in ventilov

Pred nošenjem preverite masko, filtre, glavne trakove, vdihavne/izdihavne ventile in tesnilne obroče zaradi poškodb, onesnaženja ali deformacij.

Brezplacni opomniki za vzdrzevanje

Usklajeno z datumom nakupa. Vedno brezplacno, odjavite se lahko kadar koli.

Z oddajo se strinjate s politiko zasebnosti. Od prejemanja se lahko odjavite z enim klikom v katerem koli e-sporocilu.
M: qwen/qwen3.8-flash

Zastavite Vprašanje

0/1000

Ali priporočate Series 9000 EasyLock?

Da Ne

Najpogostejša vprašanja Vprašanja

A

Ne, ta dihalni aparat ne dovaja kisika. Namenjen je izključno uporabi v območjih z zadostno prezračevanjem, ki vsebujejo vsaj 19,5 odstotka prostornine kisika.

Je ta odgovor koristen?

A

Priporočljivo je očistiti masko po vsaki uporabi. Če se ne uporablja, jo je treba očistiti vsaj vsakih šest mesecev, da se prepreči kopičenje onesnaženja.

Je ta odgovor koristen?

A

Okvirji očal, ki segajo pod tesnilno linijo, bodo ovirali pravilno tesnilo. Lahko uporabite opcionalni nosilec za očala, vendar se prepričajte, da okvir ne prelomi tesnjenja.

Je ta odgovor koristen?

A

Takoj morate zapustiti delovno območje in zamenjati respiratorsko masko. Vonjanje ali okus nevarnih snovi kaže na kršitev tesnjenja ali nasičenost filtra.

Je ta odgovor koristen?

A

Da, izdelek ne vsebuje nobenih kovinskih delov, ki bi lahko povzročili vnetje v potencialno eksplozivnih okoljih, zato je varen za taka okolja.

Je ta odgovor koristen?

A

Izvedite preizkus tesnjenja z dlanjo nad odprtino filtra in počasi vdihnite. Če se maska rahlo skrči, je tesnjenje pravilno. Alternativno pokrijte izdihovalni ventil in nežno izdihnite, da preverite puščanje.

Je ta odgovor koristen?

M: QW-35-FL

Prednosti in Slabosti

Prednosti

  • Ustreza standardu EN 136:1998 CL2 za visoko raven zaščite dihal
  • Sistem trakov EasyLock omogoča hitro in natančno prilagoditev
  • Kompatibilen z širokim naborom filtrov za delce P1, P2, P3 in plinskega razreda
  • Brez kovinskih delov zmanjšuje tveganje vnetja v potencialno eksplozivnih okoljih
  • Jasna leča iz policarbonata z integracijo opcionalnega nosilca za očala
VS

Slabosti

  • Zahteva strog upoštevanje vzdrževalnih urnikov za zagotovitev dolge življenjske dobe
  • Brada ali dlake na obrazu lahko preprečijo dosego pravilnega tesnjenja
  • Roke očal, ki segajo pod tesnilno linijo, lahko ogrozijo tesnjenje
  • Ventili se lahko zamrznejo, če so izpostavljeni nizkim temperaturam z prisotno vlago
  • Izbira filtra mora ustreza specifičnim vrstam onesnaževal in koncentracijam natančno
M: QW-35-FL

Izdelek Specifikacija

Značilnosti

Ventil, obrazni ščitnik, štirikratni pas, nastavljiv, zamenljiv filter

M: QW-35-FL

Opis izdelka

Zaščitite svoja pljuča z respiratorjem Moldex Series 9000 EasyLock

Respirator Moldex Series 9000 EasyLock z dihalno masko predstavlja vrhunsko osebno zaščitno opremo, zasnovano za zahtevna industrijska okolja. Ta robustna dihalna maska ponuja celovito zaščito pred širokim naborom nevarnih snovi, vključno s strupenimi plini, hlapi in delci. Zasnovan tako, da izpolnjuje stroge standarde EN 136:1998 CL2, zagotavlja, da so uporabniki zaščiteni pred življenjsko nevarnimi onesnaževalci, hkrati pa ohranja udobje pri daljšem nošenju.

Ena od izstopajočih lastnosti tega respiratorja je njegov inovativni sistem EasyLock, ki poenostavi postopek obleke in razobleke maske. Glavne trakove imajo štiri točke prilagoditve, kar omogoča prilagojen prileganje različnim oblikam obraza. Pravilno prileganje je ključnega pomena; maska mora ustvariti zrakotesno tesnilo okoli ust in brade brez zapiranja las ali motenj okvirjev očal. Uporabnikom svetujemo, da opravita preizkus negativnega in pozitivnega tlaka pred vstopom v kakršno koli kontaminirano območje, da preverita integriteto tesnjenja.

Vzdrževanje in higiena sta ključna pri uporabi dihalne zaščite. Priporočilo navodil priporoča čiščenje obrazne plošče po vsaki uporabi s toplo vodo, ki ne presega 50 stopinj Celzija. Za globlje sanitiranje lahko uporabimo nevtralna čistila in razkužila na osnovi alkohola. Ključno je odstraniti filter, očistiti notranje komponente maske in pregledati ventile za usedline ali poškodbe pred shranjevanjem. Maska mora biti vedno shranjena v suhem, neonesnaženem okolju stran od neposredne sončne svetlobe in virov toplote, da se prepreči degradacija materiala.

Versatilnost je še ena ključna vidik serije 9000. Podpira različne filtre, od filtrov P1 za delce, ki nudijo štirikratno mejo izpostavljenosti na delovnem mestu (WEL), do filtrov plinov razreda 2, ki nudijo do 20-krat WEL ali 5000 ppm. Specifični modeli, kot so 9004, 9005 in 9006, uporabljajo povezavo EN 148-1 za standardizirano pritrditev filtra. Ne glede na to, ali delate v kemični predelavi, kmetijstvu ali reševalnem odzivu, ta respirator zagotavlja zanesljivost, potrebno za varovanje vašega zdravja.

Pomembne opombe o vzdrževanju

Zmeraj zamenjajte membrano izdihovalnega ventila vsaj vsake štiri leta. Redno preverjajte nosni pokrov in glavne trake zaradi obrabe. Če maska kaže znake razpok, deformacije ali onesnaženja, jo takoj zavrzite. Nikoli ne spreminjajte strukture maske, saj to razveljavi garancije in ogrozi varnost.

M: QW-35-FL

© Copyright 2026 Manual.ly